{"id":2147,"date":"2022-05-06T12:09:22","date_gmt":"2022-05-06T12:09:22","guid":{"rendered":"https:\/\/blogs.cardiff.ac.uk\/bioimaging\/?p=2147"},"modified":"2022-05-06T12:10:20","modified_gmt":"2022-05-06T12:10:20","slug":"core-equipment-new-zeiss-celldiscoverer-7-system","status":"publish","type":"post","link":"https:\/\/blogs.cardiff.ac.uk\/bioimaging\/core-equipment-new-zeiss-celldiscoverer-7-system\/","title":{"rendered":"CORE EQUIPMENT: New Zeiss Celldiscoverer 7 system"},"content":{"rendered":"<div id=\"attachment_2164\" style=\"width: 2570px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/blogs.cardiff.ac.uk\/bioimaging\/wp-content\/uploads\/sites\/492\/2022\/04\/CD7-training-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2164\" class=\"wp-image-2164 size-full\" src=\"http:\/\/blogs.cardiff.ac.uk\/bioimaging\/wp-content\/uploads\/sites\/492\/2022\/04\/CD7-training-scaled.jpg\" alt=\"\" width=\"2560\" height=\"1920\" srcset=\"https:\/\/blogs.cardiff.ac.uk\/bioimaging\/wp-content\/uploads\/sites\/492\/2022\/04\/CD7-training-scaled.jpg 2560w, https:\/\/blogs.cardiff.ac.uk\/bioimaging\/wp-content\/uploads\/sites\/492\/2022\/04\/CD7-training-1536x1152.jpg 1536w, https:\/\/blogs.cardiff.ac.uk\/bioimaging\/wp-content\/uploads\/sites\/492\/2022\/04\/CD7-training-2048x1536.jpg 2048w, https:\/\/blogs.cardiff.ac.uk\/bioimaging\/wp-content\/uploads\/sites\/492\/2022\/04\/CD7-training-624x468.jpg 624w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/a><p id=\"caption-attachment-2164\" class=\"wp-caption-text\">Above: Training on the Bioimaging Hub&#8217;s new Zeiss Celldiscover7 imaging system<\/p><\/div>\n<p>The Bioimaging Hub has recently taken delivery of a state-of-the-art, automated\u00a0 live cell imaging system to replace its old <a href=\"https:\/\/www.cardiff.ac.uk\/research-equipment\/equipment\/view\/confocal-laser-scanning-microscope-with-inverted-stand\">Leica SP2 confocal microscope<\/a>.<span style=\"font-size: 1rem\"> The <a href=\"https:\/\/www.youtube.com\/watch?v=ASj3VPzc7OA\">Celldiscoverer7 imaging system<\/a>, which was purchased via the generous support of Cardiff University&#8217;s Research Infrastructure Fund (Lead Applicant: <a href=\"https:\/\/www.cardiff.ac.uk\/people\/view\/81187-hayes-anthony-j.\">Dr Tony Hayes<\/a>), has the latest <a href=\"https:\/\/www.zeiss.com\/microscopy\/int\/products\/confocal-microscopes\/lsm-980.html\">Zeiss LSM 900 confocal scan head with Airyscan 2 detector technology<\/a> and is capable of multi-format, high-throughput and super-resolution analysis of a wide range of samples from cell cultures to small model organisms. The system supports photomanipulation via FRAP, FRET and related techniques and is furnished with a comprehensive Zen software package that includes modules for deconvolution and machine learning, amongst other cutting edge features. Further details of the system are available through the Bioimaging Hub&#8217;s <a href=\"https:\/\/www.cardiff.ac.uk\/research-equipment\/equipment\/view\/automated-high-throughput-microscope-for-multi-dimensional-live-cell-imaging\">research equipment database<\/a>.<\/span><\/p>\n<p>AJH<\/p>\n<p>Find out more:<\/p>\n<ul>\n<li><a href=\"https:\/\/www.zeiss.com\/microscopy\/int\/about-us\/press-releases\/2019\/zeiss-celldiscoverer-7.html\">Zeiss Celldiscoverer 7<\/a>: Automated microscope for gentle and fast confocal 4D imaging<\/li>\n<li><a href=\"https:\/\/www.zeiss.com\/microscopy\/int\/products\/imaging-systems\/celldiscoverer-7-automated-microscope-for-live-cell-imaging.html?vaURL=www.zeiss.com\/celldiscoverer\">Zeiss Celldiscoverer 7<\/a>: Your automated microscope for live cell imaging<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The Bioimaging Hub has recently taken delivery of a state-of-the-art, automated\u00a0 live cell imaging system to replace its old Leica SP2 confocal microscope. The Celldiscoverer7 imaging system, which was purchased via the generous support of Cardiff University&#8217;s Research Infrastructure Fund (Lead Applicant: Dr Tony Hayes), has the latest Zeiss LSM 900 confocal scan head with [&hellip;]<\/p>\n","protected":false},"author":908,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[17,22],"tags":[26,25],"class_list":["post-2147","post","type-post","status-publish","format-standard","hentry","category-equipment","category-news","tag-cd7","tag-celldiscoverer-7"],"meta_box":[],"_links":{"self":[{"href":"https:\/\/blogs.cardiff.ac.uk\/bioimaging\/wp-json\/wp\/v2\/posts\/2147","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blogs.cardiff.ac.uk\/bioimaging\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blogs.cardiff.ac.uk\/bioimaging\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blogs.cardiff.ac.uk\/bioimaging\/wp-json\/wp\/v2\/users\/908"}],"replies":[{"embeddable":true,"href":"https:\/\/blogs.cardiff.ac.uk\/bioimaging\/wp-json\/wp\/v2\/comments?post=2147"}],"version-history":[{"count":9,"href":"https:\/\/blogs.cardiff.ac.uk\/bioimaging\/wp-json\/wp\/v2\/posts\/2147\/revisions"}],"predecessor-version":[{"id":2166,"href":"https:\/\/blogs.cardiff.ac.uk\/bioimaging\/wp-json\/wp\/v2\/posts\/2147\/revisions\/2166"}],"wp:attachment":[{"href":"https:\/\/blogs.cardiff.ac.uk\/bioimaging\/wp-json\/wp\/v2\/media?parent=2147"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blogs.cardiff.ac.uk\/bioimaging\/wp-json\/wp\/v2\/categories?post=2147"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blogs.cardiff.ac.uk\/bioimaging\/wp-json\/wp\/v2\/tags?post=2147"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}